Portable Power Station Runtime Calculator

Editorial team, built with AI assistance, checked against DOE FEMP / ENERGY STAR refrigerator annual kWh, Virginia Cooperative Extension, Sandia CEC inverter data, a LiFePO4 cell datasheet, Liberty Pumps, ResMed, NRDC and DOE FEMP lighting figures, updated .

Direct answer: estimated run time (hours) = station capacity (Wh) × usable share × inverter efficiency ÷ average load watts. Average load = Σ(running watts × quantity × duty cycle %). Worked fridge example: a 1,024 Wh station at 80% usable (LiFePO4 cycle-life DoD from a cell datasheet) and 90% inverter efficiency has 1,024 × 0.80 × 0.90 = 737.28 Wh of AC energy. A DOE FEMP ENERGY STAR example top-freezer (18.1 ft³) uses 363.5 kWh/yr; average watts = 363.5 × 1,000 ÷ 8,760 ≈ 41.5 W (cycling already folded into the annual figure, so duty = 100%). 737.28 ÷ 41.5 ≈ 17.8 hours (about 17 h 46 min). That is an estimate — real fridges and stations vary. Motor start surge still uses a cited ~3× multiplier on compressor-on watts derived as 41.5 ÷ (1/3) ≈ 124.5 W from the BSE-301 one-third run rule, so start ≈ 374 W. People who rely on medical equipment such as a CPAP should check the device maker's guidance on battery use; run time also varies with humidifier and heater settings. This page is not medical advice.

What to measure

Usable energy from the stationStation watt-hours multiplied by usable share and inverter efficiency equals AC watt-hours available.StationWh× usable %× inv%AC Wh = capacity × usable % × inverter %
AC Wh = capacity × usable % × inverter %
Average load from duty cycleNameplate running watts times the share of time the appliance is on equals average watts drawn.Running W(nameplate)× duty %Averageload WAverage load = running watts × duty cycle ÷ 100
Average load = running W × duty %
Estimated run timeAvailable AC watt-hours divided by average load watts equals estimated hours.AC Whafter losses÷ avg WHours+ minutesRun time = AC Wh ÷ average load watts
Hours = AC Wh ÷ average load W

Worked example: Fridge example: DOE FEMP ENERGY STAR 363.5 kWh/yr → 41.5 W avg. 1,024 Wh × 80% × 90% ÷ 41.5 ≈ 17 h 46 min. Estimate only.

How it works

Estimated run time (hours) = capacity (Wh) × (usable % ÷ 100) × (inverter efficiency % ÷ 100) ÷ average load (W). Average load (W) = sum over appliances of (running watts × quantity × duty % ÷ 100). Peak running load = sum of (running watts × quantity). For a DC or USB load the inverter term is 1 (100%). Fridge preset: DOE FEMP Table 1 ENERGY STAR model annual use 363.5 kWh/yr (18.1 ft³ top-freezer, automatic defrost). Average watts = 363.5 × 1,000 ÷ 8,760 ≈ 41.5 W; duty defaults to 100% because the annual figure already includes compressor cycling. Fridge surge: BSE-301 notes motors start at about three times running current. Compressor-on watts ≈ 41.5 ÷ (1/3) ≈ 124.5 W using the same guide's one-third run rule, so start ≈ 3 × 124.5 ≈ 374 W. Sump surge uses Liberty Pumps 250-Series locked-rotor ÷ full-load amps (8 ÷ 5.2 ≈ 1.54×). Sump duty defaults to 5% (~1.2 h/day) as an editable assumption shown on the row — real sump runtime depends heavily on rainfall and water table; it is not a published standard.

More worked examples

  1. Fridge on a 1,024 Wh station (defaults): usable AC 737.28 Wh ÷ 41.5 W ≈ 17.77 h (17 h 46 min).
  2. Same fridge on a 2,048 Wh station at 80%/90%: 1,474.56 ÷ 41.5 ≈ 35.53 h (35 h 32 min).
  3. CPAP at 53 W continuous on 512 Wh, 80% usable, 90% inverter: 368.64 ÷ 53 ≈ 6.96 h (6 h 57 min). Humidifier settings change this.
  4. Wi-Fi router 5.7 W + LED 11 W + laptop 50 W (all 100% duty) on 256 Wh, 80%/90%: 184.32 ÷ 66.7 ≈ 2.76 h (2 h 46 min).
  5. Sump pump 598 W at 5% duty (editable assumption) alone on 1,024 Wh, 80%/90%: average 29.9 W → 737.28 ÷ 29.9 ≈ 24.66 h. Storms can raise duty a lot — edit the percentage.
  6. DC/USB-only loads: 256 Wh pack at 80% usable with inverter 100% and 20 W USB draw → 204.8 ÷ 20 = 10.24 h (10 h 14 min).
  7. Space heater 1,500 W at 100% duty on 3,600 Wh, 80%/90%: usable AC 2,592 Wh ÷ 1,500 = 1.73 h (1 h 44 min) — heaters drain stations quickly.
  8. Side-by-side ENERGY STAR about 630 kWh/yr (ENERGY STAR 2024 Quick Reference): 630 × 1,000 ÷ 8,760 ≈ 71.9 W average; on 1,024 Wh at 80%/90% → 737.28 ÷ 71.9 ≈ 10.3 h.

How to measure

  1. Read the power station label for Wh (or Ah and volts: Wh ≈ Ah × V) and any usable-capacity note.
  2. Read each appliance nameplate for watts (or amps × volts). A plug-in watt meter shows real running watts and cycling.
  3. For fridges, prefer the EnergyGuide or ENERGY STAR annual kWh: average W = kWh/yr × 1,000 ÷ 8,760 (duty already included). If you only have compressor running watts, BSE-301's ÷3 rule is a sourced duty starting point.
  4. Enter the station inverter's continuous and surge watts from its specs if you want the surge warning.
  5. For CPAP and other medical devices, follow the maker's published battery and power guidance.

Common mistakes

Assumptions

Frequently asked questions

How long will a power station run a fridge?

Using the ENERGY STAR/FEMP average-watts fridge and defaults: 1,024 Wh × 80% × 90% ÷ 41.5 W ≈ 17.8 hours (about 17 h 46 min). Change capacity, usable share, efficiency and your fridge's measured or labeled kWh/yr for a better estimate.

How do you calculate power station run time?

Hours = Wh × usable share × inverter efficiency ÷ average load watts. Average load adds each appliance's watts × quantity × duty cycle.

What is a fridge duty cycle?

Compressors cycle on and off. This page's fridge preset uses average watts from annual ENERGY STAR/FEMP kWh (duty already folded in at 100%). If you enter nameplate running watts instead, BSE-301's divide-by-3 rule (~33% duty) is a sourced starting point for compressor cycling.

How many watts does a refrigerator use?

DOE FEMP's ENERGY STAR example top-freezer (18.1 ft³) is 363.5 kWh/yr → 363.5 × 1,000 ÷ 8,760 ≈ 41.5 W on average. Nameplate running watts when the compressor is on are higher; a plug-in watt meter shows both.

Will a power station start a fridge or sump pump?

Motors draw a short start surge. BSE-301 notes motors start at about three times running current. Enter your station's surge rating to see a warning if the estimated start watts exceed it. This is not a substitute for the maker's specs.

How long will a station run a CPAP?

A typical figure from one manufacturer's clinical guide is 53 W (57 VA) with humidifier. At 1,024 Wh × 80% × 90% ÷ 53 ≈ 13.9 hours. Humidifier and heater settings change draw; follow the device maker's battery guidance. Not medical advice.

What does usable capacity mean?

Some of the rated Wh may be reserved by the battery-management system. This page defaults to 80% usable to match the Lithium Werks LiFePO4 datasheet cycle-life rating at 80% DoD. Edit to your station's stated usable Wh or DoD when listed.

DC or USB loads vs the AC outlet?

Check DC/USB load to set inverter efficiency to 100%. AC outlets go through the inverter (default 90%).

Related calculators

Sources

Formulas and reference values are from these sources. Page content last updated 2026-10-28.