Room Heating BTU Calculator (Rough Estimate)

Editorial team, built with AI assistance, checked against Nebraska and Kentucky Extension rules of thumb, updated .

Enter the room's length and width for a rough estimate of the heat output, in Btu per hour, a room heater might need. It uses a simple rule of thumb from university extension guides, so treat it as a starting point: sizing a furnace, boiler or heat pump needs a proper load calculation (ACCA Manual J) by a qualified professional.

What to measure

Room floor areaTop view of a room with length and width marked.Room lengthRoom widthFloor area = length × width
Room: length × width

Worked example: University of Nebraska-Lincoln Extension's example: a 20 × 20 ft room is 400 sq ft × 28 = 11,200 Btu per hour. That is 11,200 ÷ 3.412 = about 3,282 W (3.28 kW), a little more than two 1,500 W heaters' worth.

Room heating BTU quick table (28 Btu per sq ft)

RoomRough heat estimateElectric equivalent
10 × 10 ft (100 sq ft, 9.3 m²)2,800 Btu/h0.82 kW
10 × 12 ft (120 sq ft, 11.1 m²)3,360 Btu/h0.98 kW
12 × 12 ft (144 sq ft, 13.4 m²)4,032 Btu/h1.18 kW
12 × 15 ft (180 sq ft, 16.7 m²)5,040 Btu/h1.48 kW
15 × 20 ft (300 sq ft, 27.9 m²)8,400 Btu/h2.46 kW
20 × 20 ft (400 sq ft, 37.2 m²)11,200 Btu/h3.28 kW
20 × 25 ft (500 sq ft, 46.5 m²)14,000 Btu/h4.10 kW

28 Btu per hour per sq ft is the rule of thumb in University of Nebraska-Lincoln and University of Kentucky Extension guides for choosing a room heater. It is a rough starting point, not a heat-loss calculation.

How it works

Heat needed (Btu per hour) ≈ floor area (sq ft) × Btu per sq ft. The University of Nebraska-Lincoln Extension NebGuide on space heaters says to estimate Btu requirements by taking the square feet of floor area to be heated times 28, with the example of a 20 × 20 ft room: 400 sq ft × 28 = 11,200 Btu/h. University of Kentucky Extension gives the same rule (18 × 20 ft × 28 = 10,080 Btu). Watts = Btu per hour ÷ 3.412, because 1 kWh = 3,412 Btu (U.S. EIA); kW = watts ÷ 1,000.

More worked examples

  1. University of Kentucky Extension's example: an 18 × 20 ft room, 360 sq ft × 28 = 10,080 Btu/h, which it rounds to a 10,000 Btu heater.
  2. A 12 × 12 ft bedroom: 144 sq ft × 28 = 4,032 Btu/h = about 1,182 W, within one 1,500 W heater's 5,118 Btu/h.
  3. Metric: a 4 × 5 m room is 20 m² = 215.3 sq ft × 28 = about 6,028 Btu/h = 1.77 kW.

How to measure

  1. Measure the room's length and width at floor level, wall to wall.
  2. For an L-shaped room, split it into rectangles, work out each area with the square footage calculator, and enter the total as length × 1.
  3. Note anything that makes the room harder to heat (many windows, outside walls, high ceilings, poor insulation). This rule of thumb does not account for them.

Common mistakes

Assumptions

Frequently asked questions

How many BTU do I need per square foot?

A common extension rule of thumb for a room heater is 28 Btu per hour per sq ft (University of Nebraska-Lincoln and University of Kentucky Extension). It is rough: well-insulated rooms may need less and drafty or cold-climate rooms more, which is why heating systems are sized with a Manual J calculation.

How many BTU to heat a 20 × 20 room?

400 sq ft × 28 = 11,200 Btu per hour by the extension rule of thumb, about 3.3 kW of electric heat.

How many BTU to heat a 12 × 12 room?

144 sq ft × 28 = 4,032 Btu per hour, about 1.2 kW. One 1,500 W electric heater gives about 5,118 Btu/h.

How much area will a 1,500 W heater heat?

1,500 W × 3.412 = about 5,118 Btu/h. At 28 Btu per sq ft that matches about 183 sq ft, but only as a rough guide; insulation and climate change it a lot.

Can I size a furnace or heat pump with this?

No. The U.S. DOE says rules of thumb lead to oversized systems and points to ACCA Manual J. Ask a qualified HVAC contractor for a Manual J load calculation for the whole house.

How do I convert BTU per hour to watts?

Divide by 3.412: 11,200 Btu/h ÷ 3.412 = about 3,282 W. To go the other way, multiply watts by 3.412.

Related calculators

Sources

Formulas and reference values are from these sources. Page content last updated 2026-10-27.